1 Prepare the installation

Have the gateway, KNX bus connection, 12-30 VDC auxiliary supply, network connection, ETS application and inverter configuration access ready. Check compatibility and firmware in Sections 3 and 10.

2 Connect and power the gateway

Connect KNX at the top. Connect auxiliary power and RJ45 Ethernet at the bottom. Connect the equipment to the same local network. The green Network LED confirms the Ethernet link; see Section 3.

3 Configure the inverter connection

Enable Modbus TCP or configure the required inverter connection using Section 4. Confirm the inverter address, port and Unit ID.

Open 192.168.1.51 from a laptop on a compatible network and assign an appropriate fixed gateway IP address. Set Mode to Connect, Server IP to the inverter address, Server Port to 1502 and Unit ID to 71.

5 Configure the KNX device in ETS

Assign a free physical address. Set Inverter model to 5. Set the AC network, applicable PV circuits, refresh rate and available equipment. Set Device Options to 9 for default register addressing. See Sections 5 and 6.

Assign group addresses to the required objects. Press P when ETS requires programming mode and perform a full application download for initial commissioning. See Section 5.

7 Validate data and enable logic

Check the Connected LED and Module status (GO 1 = 0). Read firmware (GO 2), wait for the polling interval and compare live values with the inverter. Check power directions and optional equipment before enabling logic. See Section 7.

Commissioning is complete when

The network and inverter links are established, the ETS download succeeds, and the required group objects return plausible values for the installed equipment.

Manual navigation

All chapters of the INV-KNX Kostal user manual

Domande frequenti

Cosa deve essere pronto prima della messa in servizio?

Prepara il gateway, un’alimentazione ausiliaria 12–30 VDC, bus KNX e collegamenti di rete, l’applicazione ETS corretta e l’accesso alla configurazione dell’inverter.

Il LED Network dimostra che la messa in servizio è completa?

No. Il LED Network conferma il collegamento Ethernet fisico. Controlla anche la comunicazione con l’inverter tramite Connected, completa il download ETS e confronta i valori KNX richiesti.

Quando devo attivare l’automazione basata sui dati dell’inverter?

Verifica prima lo stato del modulo, attendi l’intervallo di polling, confronta le misure e controlla la direzione della potenza e le apparecchiature opzionali.