Naar de inhoud
Elausys

KNX Gateways voor Omvormers / INV-KNX Huawei gebruikershandleiding

Netwerk- en omvormerconfiguratie

Netwerkinstellingen van de gateway en Huawei-configuratie voor het tot stand brengen van Modbus-communicatie.

elausys · 12 september 2026
Op deze pagina

Webconfiguratie van de gateway

[object Object]

ConnectionModeGateway Modbus settings
SUN2000 via SmartDongleConnectServer IP: SmartDongle IP

Server Port: 502

Unit ID: 1 | | EMMA | Connect | Server IP: EMMA IP

Server Port: 502

Unit ID: 0 | | SUN2000L | Listen | Server Port: 502 Unit ID: 0 |

Verbindingscontrole

Controleer na het instellen van het toepassingsmodel en de communicatieparameters of de Connected-led brandt. De Network-led bevestigt alleen de fysieke Ethernetverbinding en geen geldige omvormergegevens op KNX.

Huawei configureren

SUN2000 Series using a SmartDongle:

From the Fusion Solar portal, verify that the SmartDongle software version is >= SPC120.

If the software version is not up to date, there are two ways to perform the firmware upgrade:

  1. Local via APP

You can download the latest version from Huawei homepage.

https://support.huawei.com/enterprise/en/digital-power/sdongle-pid-23826585/software

  1. Upgrade via Portal:

Plants > Upgrade Management > Add

Select Device type: Smart Dongle > SPC 120 and Device

In the FusionSolar application, modbus should be enabled:

EMMA-verbindingsinstellingen

  1. Connection of the EMMA must be via LAN, as WLAN does not work:
  • Open the Fusion Solar App with installer credentials
  • Go to Connect EMMA > Communication configuration > Router configuration
  • Select LAN
  1. For the physical LAN connection, use the WAN port on the EMMA, NOT the LAN port.
  2. Ensure the Gateway is in the same (V)LAN as the EMMA.
  3. Activate Modbus on EMMA:
  • Via the Fusion Solar app with the installer credentials
  • Navigate to Services > "Commissioning the device" in the Settings
  • Go to Communication configuration
  • Enable Modbus TCP connection
  • Turn TLS off
  • Set the Elausys GATEWAY address as the client IP address

SUN2000L-verbindingsinstellingen

The following procedure applies to SUN2000L inverters.

Install the Huawei mobile application “FusionHome” on your smartphone.

If your inverter is not yet connected to the WIFI network, follow the instructions from the video below :

https://www.youtube.com/watch?v=EDbOp_GlXDE

In the application, select your inverter and login using the installer code. Default code is 00000a

From the home page choose “Communication configuration”, set the management system connection parameters:

  • Set at domain name: IP address of the KNX gateway
  • Assure that the port is 502 and encrypted transmission is disabled.
  • After you set the domain name and the port, press “Connect”
  • Check that the connection with the KNX gateway is established on the front panel of the KNX gateway, the status LED “Connected” should be ON.

All chapters of the INV-KNX Huawei user manual

Veelgestelde vragen

Wat is het fabrieks-IP-adres van de gateway?

Het fabrieksadres is 192.168.1.51. Gebruik een laptop die dit adres kan bereiken, wijs een geschikte vrije vaste IP-adres toe en verbind opnieuw via het nieuwe adres.

Welke Modbus-verbindingsinstellingen moet ik gebruiken?

Gebruik voor SUN2000 via SmartDongle de modus Connect, poort 502 en Unit ID 1. Gebruik voor EMMA Connect, poort 502 en Unit ID 0. SUN2000L gebruikt Listen, poort 502 en Unit ID 0, waarbij de omvormer verbinding maakt met de gateway.

Welke fysieke poort moet ik op EMMA gebruiken?

Selecteer LAN in de routerconfiguratie van EMMA, maar sluit de Ethernetkabel aan op de fysieke WAN-poort. Houd EMMA en de gateway op dezelfde VLAN. Schakel Modbus TCP in, schakel TLS uit en stel het gateway-IP-adres in als toegestane client.

Verder verkennen

Vind de andere handleidingen voor dit product in de documentatie.