PRT3 communication options
In the PRT3 Options tab, enable the serial port, select Home Automation, set 9600 baud and select ASCII Protocol.
Enable event reporting and the required functions in the following settings. If communication does not start, verify Section 016 from the keypad as described in Troubleshooting.
Areas and zones
Select the areas and zones that should be enabled in the interface.
Virtual inputs and PGM
When virtual inputs or PGM are required, enable and configure them in their respective tabs.
Report options
In Report Options / Messages, select everything under Report Options 1 and 2.
| Section | Report option | Required setting |
|---|---|---|
| 901/1 | Global security report | Enabled |
| 901/2 | System armed/disarmed | Enabled |
| 901/3 | Entry/exit delay | Enabled |
| 901/4 | Zone in alarm / alarm restore (zones 01 to 80) | Enabled |
| 901/5 | Fire alarm / fire alarm restore | Enabled |
| 901/6 | Silent alarm / silent alarm restore | Enabled |
| 901/7 | Panic alarm | Enabled |
| 902/1 | Low battery / battery restored (zones 01 to 80) | Enabled |
| 902/2 | AC failure / AC failure restore | Enabled |
| 902/3 | Ready to arm / not ready to arm | Enabled |
| 902/4 | Zone open / zone OK (zones 01 to 80) | Enabled |
| 902/5 | Zone tamper / tamper restore (zones 01 to 80) | Enabled |
| 902/6 | Zone bypassed (zones 01 to 80) | Enabled |
| 902/7 | User code entered on keypad | Enabled |
| 902/8 | TLM trouble / TLM trouble restore | Enabled |