General
| GO | Name | Description |
|---|---|---|
| 1 | Module status | 0: operating normally. 2: no communication with the Ajax system for 3 minutes. 4: no Ethernet connection. |
| 2 | Firmware | Sends the firmware version of the device at startup. |
| 233 | Call scene | The scene number configured for each area status is sent to KNX whenever the area status is activated. |
PG
Each PG has 2 group objects:
| GO | Name | Description |
|---|---|---|
| 3 | PG1 | Switches the Ajax relay or socket assigned to PG 1 |
| 4 | PG1 Status | State of the relay or socket, or camera event, assigned to PG 1 |
The same structure applies to PG 2 to PG 32 (GO 5 to 66).
Power Supply
| GO | Name | Description |
|---|---|---|
| 163 | AC Failure | Active when the main power supply of the alarm system is down. |
| 164 | Battery Failure | Active when the battery is low. |
Zone
Each zone has 1 group object for status to KNX:
| GO | Name | Description |
|---|---|---|
| 67 | Zone x Status | Zone status (x = 1 to 96) |
The same group object structure applies to all zones.
Virtual Inputs
| GO | Name | Description |
|---|---|---|
| 169 | Virtual input 1 | ON runs the action assigned to VI 1 (panic alarm, photo) |
The same structure applies to virtual inputs 2 to 16 (GO 170 to 184).
Area
Each area has 12 group objects: 3 for area control and 9 for area status to KNX.
| GO | Name | Description |
|---|---|---|
| 185 | Area x – Arm | Arm the group |
| 186 | Area x – Partial arm | Enable/Disable Night Mode for the complete Hub |
| 187 | Area x – Disarm | Disarm the group |
| 188 | Area x – State disarmed | Area x status |
| 189 | Area x – Entry delay | Area x status (NOT USED for AJAX) |
| 190 | Area x – Exit delay | Area x status (countdown of two-stage arming) |
| 191 | Area x – State armed | Area x status |
| 192 | Area x – State partial armed | Area x status (Night Mode) |
| 193 | Area x – Fire alarm | Area x status |
| 194 | Area x – Siren ON | Area x status (NOT USED for AJAX) |
| 195 | Area x – Panic alarm | Area x status |
| 196 | Area x – Intrusion alarm | Activated when armed partition + detector alarm (BA); auto-reset on disarm |
The same group object structure applies to all areas (x = 1 to 4).